Skip to content

광류 센서 ​

Optical Flow uses a downward facing camera and a downward facing distance sensor for velocity estimation. It can be used to determine speed when navigating without GNSS — in buildings, underground, or in any other GNSS-denied environment.

The video below shows PX4 holding position using the Ark Flow sensor for velocity estimation in Position Mode:

The image below shows an optical flow setup with a separate flow sensor (PX4Flow) and distance sensor (Lidar-Lite):

Optical flow lidar attached

설정 ​

An Optical Flow setup requires a downward facing camera and a downward facing distance sensor (preferably a LiDAR). These can be combined in a single product, such as the ARK Flow, ARK Flow MR and Holybro H-Flow, or they may be separate sensors.

The sensor(s) can be connected via MAVLink, I2C or any other bus that supports the peripheral. Up to two optical flow sensors can be used at the same time (see Multiple Optical Flow Sensors).

INFO

If connected to PX4 via MAVLink the Optical Flow camera sensor must publish the OPTICAL_FLOW_RAD message, and the distance sensor must publish the DISTANCE_SENSOR message. The information is written to the corresponding uORB topics: DistanceSensor and ObstacleDistance.

다른 방향으로 이동할 때의 흐름 출력은 다음과 같아야합니다.

기체 이동통합 흐름
전방+ Y
후방- Y
우측- X
좌측+ X

INFO

The integrated flow values are angular measurements (radians) representing rotation of the image about the sensor's body axes using the right-hand convention. They are not translational displacements along those axes, which is why forward vehicle movement (along X) appears in the Y flow axis, and rightward movement (along Y) appears in the X flow axis. Specifically, forward movement causes the ground image to rotate about the Y axis (+ Y), while rightward movement causes a negative rotation about the X axis (- X).

광류 데이터는 다른 속도 데이터 소스와 융합됩니다. The approach used for fusing sensor data and any offsets from the center of the vehicle must be configured in the estimator.

Scale Factor ​

For pure rotations the OPTICAL_FLOW_RAD.integrated_xgyro and OPTICAL_FLOW_RAD.integrated_x (respectively integrated_ygyro and integrated_y) have to be the same. If this is not the case, the optical flow scale factor can be adjusted using SENS_FLOW0_SCALE.

TIP

The low resolution of common optical flow sensors can cause slow oscillations when hovering at a high altitude above ground (> 20m). Reducing the optical flow scale factor can improve the situation.

유량 센서/카메라 ​

Agam FloRange ​

Agam FloRange is a DroneCAN optical flow sensor, distance sensor, and IMU. It has a PixArt PAA3905 optical flow sensor, Broadcom AFBR-S50LV85D 30-metre distance sensor, and InvenSense ICM-42688-P 6-Axis IMU.

ARK Flow & ARK Flow MR ​

ARK Flow is a DroneCAN optical flow sensor, distance sensor, and IMU. It has a PAW3902 optical flow sensor, Broadcom AFBR-S50LV85D 30 meter distance sensor, and Invensense ICM-42688-P 6-Axis IMU.

ARK Flow MR is a DroneCAN optical flow sensor, distance sensor, and IMU, for mid-range applications. It has a PixArt PAA3905 optical flow sensor, Broadcom AFBR-S50LX85D 50 meter distance sensor, and Invensense IIM-42653 6-Axis IMU.

Holybro H-Flow ​

The Holybro H-Flow is a compact DroneCAN optical flow and distance sensor module. It combines a PixArt PAA3905 optical flow sensor, a Broadcom AFBR-S50LV85D distance sensor, and an InvenSense ICM-42688-P 6-axis IMU. An all-in-one design that simplifies installation, with an onboard infrared LED enhances visibility in low-light conditions.

PMW3901 기반 센서 ​

PMW3901 is an optical flow tracking sensor similar to what you would find in a computer mouse, but adapted to work between 80 mm and infinity. It is used in a number of products, including some from: Bitcraze, Tindie, CubePilot, Thone and Alientek.

기타 카메라 / 센서 ​

카메라 통합 보드를 사용할 수 있습니다. For this the Optical Flow repo can be used (see also snap_cam).

거리 측정기 ​

You can use any supported distance sensor. 그러나 견고성과 정확성 측면에서는 음향 센서보다 LIDAR를 사용하는 것이 좋습니다.

추정기 ​

추정기는 광학 흐름 센서 및 기타 소스의 데이터를 융합합니다. 융합 방법 설정과 차량 중심에 대한 상대적 오프셋이 사용되는 추정기를 지정하여야합니다.

오프셋은 아래와 같이 차량 방향 및 중심을 기준으로 계산됩니다.

Optical Flow offsets

Optical Flow based navigation is enabled by both EKF2 and LPE (deprecated).

Extended Kalman Filter (EKF2) ​

For optical flow fusion using EKF2, set EKF2_OF0_CTRL.

광류 센서가 차량 중앙에서 오프셋된 경우 다음 매개변수를 사용하여 설정합니다.

Parameter설명
SENS_FLOW0_POS_X바디 프레임에서 광류 초점의 X 위치 (기본값은 0.0m).
SENS_FLOW0_POS_Y바디 프레임에서 광류 초점의 Y 위치 (기본값은 0.0m).
SENS_FLOW0_POS_Z바디 프레임에서 광류 초점의 Z 위치 (기본값은 0.0m).

See Using PX4's Navigation Filter (EKF2) > Optical flow for more information.

Multiple Optical Flow Sensors ​

main (planned for PX4 v1.17)

PX4 supports up to two optical flow sensors at the same time. A second sensor can add redundancy, or extend the usable envelope by combining sensors with different operating ranges. Both sensors are fused, each at its own measurement rate. A sensor that temporarily cannot be fused (for example when it leaves its operating range) keeps being processed for monitoring, and its data is used again as soon as it recovers. A sensor whose measurements are rejected while the other sensor is still fused is considered faulty: it never resets the velocity or height above ground estimate, it is stopped and retried later.

Each sensor is bound to a parameter "slot" n (0 or 1) using its device ID:

  • SENS_FLOW0_ID and SENS_FLOW1_ID record the device ID of the sensor bound to the SENS_FLOWn_* parameters. While an ID parameter is 0 (default), the first unbound sensor that delivers data is bound to it, and the assignment is saved so that it remains stable across reboots. The EKF uses the same slot numbering: EKF2_OFn_* parameters apply to the sensor bound to SENS_FLOWn_ID.
  • Fusion is enabled per slot using EKF2_OF0_CTRL and EKF2_OF1_CTRL. Only slot 0 is enabled by default. A slot can be enabled or disabled at runtime.
  • When a sensor is replaced, the new sensor has a different device ID and is bound to the next free slot, which is not fused by default. To bind the new sensor to the old slot, set its SENS_FLOWn_ID parameter to 0 and reboot.
  • All other optical flow parameters exist once per sensor: sensor properties such as delay, rotation, and mounting position in SENS_FLOW0_*/SENS_FLOW1_*, and fusion tuning such as noise and quality thresholds in EKF2_OF0_*/EKF2_OF1_*, so each sensor can be configured independently.

Note the following requirements and behaviour:

  • All flow sensors must be mounted facing downwards. The sensors do not need to have the same yaw orientation (set individually using SENS_FLOWn_ROT), and each sensor has its own position offset (SENS_FLOWn_POS_X and so on).
  • Flow sensors are not paired with specific distance sensors. The EKF estimates a single height above ground that is used for all flow sensors, corrected for each sensor's position offset. The minimum and maximum operating distance reported by each sensor is applied individually.
  • A distance measurement provided by a flow sensor itself (as on the ARK Flow) can substitute for a missing distance sensor. Only the measurement from the first sensor that reports a distance is used for this purpose.
  • The preflight check enabled by SYS_HAS_NUM_OF passes when at least one sensor delivers valid data.

시뮬레이션 ​

Optical flow can be simulated with SIH, which computes the flow from the simulated vehicle motion instead of rendering a camera image. As with real hardware, the simulated sensor reports the integrated flow only, so a downward facing distance sensor has to be simulated alongside it — SIH provides one.

Two ready-made airframes have flow enabled and the estimator configured for it:

sh
# Multicopter navigating on optical flow only (GNSS fusion disabled)
make px4_sitl_sih sihsim_quadx_flow

# Standard VTOL navigating on optical flow only (GNSS fusion disabled)
make px4_sitl_sih sihsim_standard_vtol_flow

The sensor itself is configured with the SIH_OF_* parameters (rate, noise, and maximum ground distance).

Optical flow is also simulated by Gazebo Classic, which renders the downward facing camera image and runs flow computation on it.